Re: Fluke 8600A
It does indeed route mains to the front panel switch. They could have used a plastic shaft to activate the mains switch on this, but there is space left for various options such as a data output card and they may not have had room. The mechanical link to the mains switch on the 8800A is a strange th...
- Fri May 23, 2025 12:29 pm
- Forum: Test Equipment
- Topic: Fluke 8600A
- Replies: 3
- Views: 70
Fluke 8600A
This was bought from one of the usual traders at a swapmeet for a tenner. He deals in small bags of components for £1 each, but occasionally has TE. He said it worked and he'd used it as his bench DMM for years. The bottom segment of each 7 segment display didn't light. Opening it and wiggling the s...
- Thu May 22, 2025 11:03 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
On the original topic, the 8000A is a steaming turd of a meter. I hate them. The things have mains running on the soldermask-free board right up to the front panel. The LED displays die due to overheating. The little plastic pegs snap off the display. The ASICs in it like to blow up. Terrible DMM i...
- Thu May 22, 2025 11:28 am
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
Lindstrom side cutters are between £65 and £100 from CPC, depending which ones you buy. Ouch!
I'm sure the ones I bought are still produced. They were described as "production line quality".
I'm sure the ones I bought are still produced. They were described as "production line quality".
- Thu May 22, 2025 9:15 am
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
The other thing that followed me home were some Lindstrom pliers and full-flush side cutters. I still use them 44 years later. I also still have the side cutters and pliers I carefully chose and bought to take to university. The cutters are bigger and heavier than the Lindstrom, but are still used ...
- Tue May 20, 2025 11:16 pm
- Forum: Test Equipment
- Topic: Test Equipment Anonymous (TEA) : Discussion and Group Therapy Thread
- Replies: 3589
- Views: 1574206
Re: Test Equipment Anonymous (TEA) : Discussion and Group Therapy Thread
A good haul. Did you have a stall there? There was one gent selling SAs I thought might be you, but he said he wasn't Robert, and another bloke with his wife selling a lot of high end stuff, for a rally, but I didn't ask his name. I came back with a BC348-H (WWII USAAF receiver) in a nice state for ...
- Tue May 20, 2025 7:26 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
Tektronix 475 with DM44 is a nice combination. That's still my go-to when possible at work. Unfortunately, that also does speak to the test equipment situation at work though given it is 2025 after all. Around 1980 I had a colleague who'd worked in production in a burglar alarm factory a few years ...
- Tue May 20, 2025 10:01 am
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
It has a strange IC, part of a controller rather than an integrated controller like the ICL7126 family. FFI, see the manual. Can't hold that against Fluke; clearly they were pushing the available technology. Those 40 pin ICs were were used for control and display. They used them in several designs....
- Tue May 20, 2025 8:43 am
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
I've little appetite for polishing a boring 3.5 digit turd - and improving this is definitely whack-a-mole territory. A working 3.5 digit bench DMM is OK. It doesn't run out of battery. If it doesn't work, it's in dustbin territory. However the processor is the same as used in better models, so if ...
- Mon May 19, 2025 10:40 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
So are the prized by some CRO's of yesteryear yet their addition cost of ownership now is keeping them going..... They have a savage grandeur which many find fascinating. Valve scopes are probably now a bit too savage for most. Not all of us have the time to fix tools in order to finish a project.....
- Mon May 19, 2025 10:25 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
I've little appetite for polishing a boring 3.5 digit turd - and improving this is definitely whack-a-mole territory. A working 3.5 digit bench DMM is OK. It doesn't run out of battery. If it doesn't work, it's in dustbin territory. However the processor is the same as used in better models, so if ...
- Mon May 19, 2025 10:12 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
Based on this thread, shouldn't we declare Fluke products as a crap shoot..... Gimme a mo to grab my hat and coat.... We are talking about bench DMMs about 50 years old, which were probably designed with a design life of maybe 10 years in mind. Then they sold for $$$s painful and now are bought for...
- Mon May 19, 2025 9:50 pm
- Forum: Test Equipment
- Topic: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
- Replies: 50
- Views: 1155
Re: Fluke 8000A: makes me doubt my high opinions of Fluke DMMs
At the same event I paid £10 in cash money for a sort of assured working Fluke 8600A. You were there when I bought if. It sort of worked but the bottom segment of each LED display didn't light. That was fixed by wiggling the flex connector to the display. It may be a dry joint. Then it played up wit...
- Sat May 17, 2025 10:49 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
I bought the SDS1102CML+ pre-Covid, maybe 2018. It's small and neat and it's the one I've reached for. There a few things it doesn't do, such as serial decoding, and the channel 2 trace is a dark blue, which made it hard to see, so I've just bought a better one. I never had to use the FFT facility f...
- Sat May 17, 2025 2:13 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
It is rare[1] that newer equipment is worse than existing equipment, of course. It was poor judgement to say the least. Such highly visible poor judgement can colour marketplace perceptions for a long time ("bad then, why should I expect it to be good now" or "I'm not going to risk m...
- Sat May 17, 2025 11:53 am
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
The SDS1000 DL, CML and CML+, must have been introduced a long time ago. 15 years back or so. They were introductory models. You can certainly argue that it was poor judgement to include an FFT feature that was basically useless. The recently introduced SDS800X HD series look like the oscilloscope b...
- Sat May 17, 2025 8:10 am
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
There are all sorts of features it's easy to add to a DSO, such as voltage readings of various sorts. They are useful because you are often interested in voltage levels on a scope and they save you squinting at the display and fiddling about to refer to the scales. They are not as accurate as a chea...
- Fri May 16, 2025 10:44 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
Then you could go to a FFT exclusive display and examine the menu for axis scaling and markers to place on peaks although I'm not sure if the DL models provided them. So modern Siglent equipment is like 1960s SAs and significantly more primitive than 1970s SAs? Disappointing. Not at all. These fair...
- Wed May 14, 2025 9:27 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
So it's basically just eye candy? :roll: My crusty old eyeballs are better TE. Something they felt they could bung in, and would add to the attraction, and they could mention on the data sheets. Certainly not a well-developed feature. I don't think many reviewers caned the scopes for not having an ...
- Wed May 14, 2025 9:15 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
No scales?! Seriously? April 1st is long gone. :D That's prehistoric, or at least early 1960s. Even my 1970s and 1980s analogue spectrum analysers (Tek492, DP8562) have comprehensive readout of all the settings! It reminds me of those little scopes that came out in the 50s, where there wasn't much ...
- Wed May 14, 2025 6:04 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
From fiddling with mine, I came to the conclusion that it's a feature with window functions which produces a trace that looks a bit like an FFT display. There's not much to control it, and working out what the horizontal and vertical axes represent would be hard work or guesswork. It doesn't have th...
- Wed May 14, 2025 2:03 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
I've got a Siglent SDS1102CML+, about the same vintage as your SDS1052DL. It's better spec'd and may be a bit later. I played with the FFT function and was never very impressed or saw it as particularly useful. I may not have discovered how to drive it properly, but it seems to be a bit limited. Sor...
- Wed May 14, 2025 9:59 am
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
We've been trying to persuade him that he can't expect to get anywhere with his totally inadequate TE or his crusty old eyeballs. He thinks we are pulling his leg or maliciously leading him down rabbit holes. Perish the thought. I'm sure as an experienced Siglent salesman and self-confessed TE enabl...
- Tue May 13, 2025 9:06 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
You guys kill me. Suggesting I go down all sorts of rabbit holes. My Siglent SDS1052DL does have some basic FFT functions but I trust my crusty old eyeballs. :P :P :D I'm shocked that you so readily believe that your e-friends are trying to mislead you. These are not rabbit holes and it's nothing l...
- Tue May 13, 2025 4:28 pm
- Forum: Test Equipment
- Topic: HP 204C
- Replies: 74
- Views: 10164
Re: HP 204C
Calibration was a bit fiddly but finally fell into place. Will burn-in for at least 2 hours then this project is complete. Oh no it isn't! Not until the spectral purity of that sine wave is checked out on a spectrum analyzer! No gots a spectrum analyzer. My tired old eyeballs are good enough. :D Yo...